Absolute encoders keep their position on a battery, and a dead battery loses it, costing a re-homing at best and a crash at worst. This page explains what data the battery sustains, the voltage watch and hot-swap sequence, how the consequences are graded, and the standard no-loss replacement procedure.
Absolute encoders come single-turn and multi-turn: single-turn remembers the angle within one revolution, multi-turn also remembers the accumulated turns, up to 32767 each way. The battery sustains the counting circuit, a small logbook powered continuously so that turns made while powered down are still known at power-up. When the cell falls below the threshold, about 3.0V on a 3.6V lithium nominal, the drive alarms; the data survives for hours to days depending on model, but the battery must be changed promptly. Single-turn absolute encoders mostly need no battery at all, reading the angle straight off the code disc, so a battery implies multi-turn counting or an absolute-capable servo.
Change the battery hot, drive powered: most brands require the control supply on, and swapping with everything off loses the count the moment the old cell leaves its holder. Confirm the new cell above 3.5V, fit it within 30 seconds of removing the old one, some models allow minutes, check the manual, clear the alarm if the model needs it, and verify by moving the axis a known distance and back. The forbidden move: pulling the old battery from a powered-down drive and hunting for the new one at leisure, which wipes the count, forces a re-home, and on vertical axes needs mechanical support first to stop the drop. Watch spare-cell dates too: lithium self-discharge empties a ten-year-old shelf stock, so rotate and test every three years.
Cell life is typically five years. Put each drive battery into a ledger with its change date and order spares a month ahead of expiry; wire the low-battery alarm into the PLC system and push it to maintenance phones rather than waiting for an operator to notice a wrong position; and change multi-axis systems one axis at a time. Consequences are graded: an ordinary axis re-homes in minutes, while critical axes, tool changers and rotary tables, can crash, so those carry a mechanical home switch plus software cross-check and a slow-speed home verification before automatic duty. The whole point of absolute encoders is skipping the home cycle, and a lapsed battery discipline wastes exactly that money. And never substitute an alkaline cell for the lithium one; the capacity is an order of magnitude short.
| Checkpoint | Standard or practice | Risk | Check interval | Owner |
|---|---|---|---|---|
| Voltage monitoring | Alarm below 3.0V | Position loss | Monthly, alarm system | Electrical maintenance |
| Change timing | Immediately on alarm or before expiry | Data loss | Quarterly ledger audit | Electrical maintenance |
| Change procedure | Hot swap, power on | Crash | Per SOP | Maintenance crew |
| Spares management | Stock rotated within 3 years | Dead cell on fitting | Annual stocktake | Stores |
| Position verification | Slow-speed home on power-up | Crash or scrap | Automatic every start | PLC program |
| Ledger entries | Date, axis, voltage | Missed changes | Quarterly audit | Maintenance supervisor |
Battery management looks minor until a crash or a stoppage; fold the voltage into routine inspection, the dates into a ledger and the alarms into a push system, and position loss incidents practically vanish. Hot-swap rules differ by brand, so trust the manual, not last brand habit.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Safety per GB/T 5226.1 / IEC 60204-1; servo systems per GB/T 16439. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.