Doubling safety factors doubles cost without buying stability. This page gives reasonable margin ranges for torque, inertia ratio, voltage sag and service life, with red lines for each.
Margins come in two kinds: against uncertainty, such as load estimation error and material variation, and against ageing, such as bearing wear and insulation drift. The first kind warrants 20 to 30 percent; the second is a separate life calculation. A torque factor of 1.2 to 1.5 is normal; anything above 2 usually hides a sloppy estimate, costing size and money while dulling response. Inertia ratio is not a safety factor either: gearing down to a ratio below 1 for imagined stability only makes the axis sluggish.
Recommended values: continuous load torque factor 1.2 to 1.5, shock loads 1.5 to 2, presses 2. Accel torque capped at 80 percent of peak with 10 percent extra margin. Inertia ratio target 3 to 10, up to 15 for belt drives. Voltage sag: rated torque must survive a 10 percent grid drop, about 342 V on a 380 V supply; check the drive low-voltage specification. Winding temperature rise keeps 10 K below the insulation class limit. Bearings above 20000 hours; encoder batteries replaced at half life.
Margins must be measured, not written: on the prototype, log worst-case current and temperature against design values. Peak current at 85 percent of the drive limit is a red line, as is temperature within 10 K of the insulation limit. After volume production, sample no-load current and temperature rise every six months; a 15 percent upward trend schedules maintenance. Watch for eaten margins: cycle times quietly stretched and ramps slowed in the program are compensation for undersizing.
| Margin item | Recommended | Red line |
|---|---|---|
| Continuous torque factor | 1.2 to 1.5 times load | Above 2 hides poor estimates |
| Shock torque factor | 1.5 to 2 times | Presses checked separately |
| Accel torque | Cap at 80 percent of peak | Warn at 85 percent |
| Inertia ratio | 3 to 10 | Belt drives up to 15 |
| Voltage sag | Full load at minus 10 percent grid | Derate beyond minus 15 percent |
| Bearing life | Above 20000 hours | Caution below 10000 hours |
Present margins together with the calculations at design review; a margin without an estimate is not a margin. Recheck worst-case duty after design changes or material swaps, because margins are living numbers, not one-time approvals.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Duty factors follow GB/T 12350 and IEC 60034-1 service factor definitions; drive voltage tolerance references IEC 61800-5-1; machine safety follows GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.