Common drive alarm codes in commissioning: one table across brands

Every brand has its own code list, but the alarm families are the same ten everywhere. Current, voltage, overload, heat, phase loss and comms - with causes and field actions per class.

1. How it works

Alarm families transcend brands: overcurrent OC, instantaneous output current beyond the limit; overvoltage OU, bus above threshold; undervoltage LU, bus sagging; overload OL, current above rating for too long; overheating OH, heatsink or motor; phase loss PF; communication CE. Read every alarm with three elements: the code, the operating condition - starting, running, decelerating, stopped - and whether it resets. The same code means different things in different conditions, and that is the core of fast diagnosis.

2. Practice and pitfalls

The frequent ones: overcurrent at start means an output short, cable insulation or acceleration far too short - defaults near 5s want 10~30s on high-inertia loads; during running, look at load shocks and vector mode matching. Overvoltage on decel calls for longer decel times or a braking resistor; at idle, check the supply tap. Overload: set the electronic thermal current to the motor nameplate value, not the drive rating - the classic beginner error - then check for stalling and unbalanced phases. Overheat: fan turning, fins clear, ambient below 40C, mounting clearance 10cm at the sides and 15cm above. Undervoltage points to supply sags, aged bus capacitors or a weak upstream contact. And the rule of three: an alarm that comes back after three resets gets investigation, not another reset.

3. Drive alarm cross-reference quick table

Alarm familyTypical codesUsual causesField action
Overcurrent OCF30001, E.OC1 and kinShort accel, output shortLonger accel, check insulation
Overvoltage OUF30002, E.OV1Regen on decel, high inputLonger decel, braking unit
Overload OLF30005, E.THTThermal set to drive ratingSet to motor current, check load
Overheat OHF30004, E.FINFan, blocked fins, hot roomClean, cool, check clearance
Undervoltage LUF30003, E.UVTSupply sag, aged capacitorsCheck supply, test bus caps
Communication CEF3-family code, E.MODWiring, address, noiseCheck line, address, earthing

4. Notes

Log the code, note the condition, change one parameter, reset no more than three times. Read the manual appendix before opening the cabinet - understand the families and any brand becomes familiar within minutes.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Adjustable speed drives and their tests per GB/T 12668.2 (IEC 61800-2), machinery protection per GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Resetting past a persistent alarm: OC and OH are protection doing its job - three resets maximum, then investigate
② Setting electronic overload from the drive rating instead of the motor: protection vanishes or nags - nameplate current only
③ Memorising codes without conditions: overcurrent at start and at decel are different diseases - always read the operating state

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.