Sensorless vector drives estimate speed and flux angle from a motor model, and at low speed the estimates degrade. This page explains the three instability sources, the parameter fixes, and the point at which an encoder becomes mandatory.
Three effects gang up at low speed: back-EMF shrinks until at 1~2Hz it drowns in noise, stator resistance drifts 30~40 percent with temperature and directly skews the flux angle, and inverter dead time of 2~4 microseconds per switching period distorts the current waveform, pushing torque ripple from about 1 percent to over 10 percent near standstill.
The fix sequence: repeat motor identification, preferably rotating, which nails the stator resistance; enable dynamic voltage boost of 3~8 percent, no more or the motor overexcites; drop the carrier to 4kHz to shrink dead-time effects; and design the cycle to pass quickly through the sub-3Hz band. Verify at 1, 3 and 5Hz with 50 percent load for one minute each, current ripple within plus or minus 5 percent. If the process needs sustained operation below 1Hz, zero-speed full torque, or 0.1 percent speed accuracy, add the encoder and close the loop.
| Symptom | Main cause | Quick fix | Permanent fix |
|---|---|---|---|
| Jogging and loss of sync at 1Hz | Weak back-EMF signal | Pass through the band quickly | Encoder closed loop |
| Speed drift after warm-up | Stator resistance error | Re-identify resistance | Thermal model or encoder |
| Hairy current waveform | Dead-time effect | Carrier down to 4kHz | Dead-time compensation |
| Failed start under load | Insufficient boost | Raise boost to 5~8 percent | Vector mode plus encoder |
| Erratic torque | Model divergence | Repeat rotating ID | Move to encoder vector |
Diagnose in order: trouble only below 3Hz points to model signal weakness; periodic current spikes point to dead time; and check when identification was last done, since a cold-day ID run in summer heat guarantees low-speed trouble.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Control performance requirements for AC drives follow GB/T 12668.2 with machine safety per IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.