Integrating the vacuum generator into the valve terminal removes the standalone vacuum station. This page covers the circuit structure, holding force calculation, vacuum monitoring and leak hunting.
The integrated module packs the ejector, supply valve, release valve, filter and vacuum switch: air at 0.4 to 0.6 MPa drives the ejector to minus 60 to 90 kPa, the suction cup grips, and the release valve blows a small reverse flow to drop the part. Benefits: near-zero plumbing, vacuum buildup in 0.1 to 0.3 s, no moving parts. Drawbacks: air consumption 3 to 5 times an electric pump, so it suits pick-move-place duty rather than continuous holding.
Holding force F = A times P times eta with eta of 0.6 to 0.8 for sealing losses. Safety factors: 4 for horizontal carrying, 6 for vertical, 8 with flipping. Example: carrying a 2 kg panel horizontally needs 78.4 N; a 50 mm cup, 19.6 cm², at minus 70 kPa holds 8.2 N, so at least four cups with margin. Cup material: NBR for smooth surfaces, bellows for uneven, antistatic silicone for electronics. Sharing one vacuum circuit means one leaking cup kills the group; split into two independent circuits for critical parts.
Fit a vacuum switch set 10 percent below rated vacuum, minus 70 kPa for minus 80 kPa rated, alarming on failed grip. Leak hunting: watch the gauge after switching off; a fall beyond 10 kPa in 3 s means a leak; isolate cup branches one by one. Common culprits: worn lips, oily part surfaces, loose fittings. Inspect lips monthly, blow filters monthly, verify switch settings quarterly.
| Carry attitude | Safety factor | Cup layout |
|---|---|---|
| Horizontal | 4 times | Evenly spread cups |
| Vertical | 6 times | Larger loaded cups |
| Flipping | 8 times | Two independent circuits |
| Vacuum level | Minus 60 to 90 kPa | By surface material |
| Vacuum switch | Alarm 10 percent below rated | Mandatory |
| Buildup time | 0.1 to 0.3 s | Integrated circuit edge |
List workpiece surface conditions at design review: porous, oily or dusty surfaces will not seal; choose clamping or magnetic gripping early instead of discovering it on site. Archive cup specifications and layout; order spares by part number.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Pneumatic and vacuum elements follow GB/T 5226.1; vacuum components reference the GB/T 25371 series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.