Dust in the screw ruins accuracy in three months. This page covers choosing IP ratings, bellows and seals, and maintenance intervals for dirty duty.
IP codes read as solids then liquids: first digit 6 means dust-tight, second digit 4 splash, 6 strong jets, 7 brief immersion. Scenarios: dry electronics shops run bare IP40 modules; general machining wants IP54 with basic seals; grinding, textile or flour dust needs IP65 plus bellows; wet chips and coolant demand IP67 with stainless parts. An exposed-screw module is inherently IP20; the bellows makes the difference.
Bellows are the main defence: flame-retardant cloth for normal duty, oil-resistant for coolant, PTFE for heat. Check the compression ratio: a 600 mm stroke packs to 80 to 100 mm folded, so reserve cabinet space. The seal trio: end-cap wiper lips, screw oil seal and guideway end seals. Inspect wiper lips quarterly in dusty plants; a worn lip feeds grit straight into the nut. Belt modules need pulley covers too; dust packed in belt teeth causes tooth jumping.
Intervals: dry duty greases every six months; dusty duty blows out and inspects monthly with quarterly greasing; wet-chip duty inspects weekly and greases monthly. Use molybdenum-disulphide EP grease against abrasive dust. Seal failure signals: sludge at the slider edges, dust film on the screw, repeaterability drifting beyond 20 percent; stop and replace seals rather than grinding on.
| Environment | Protection | Interval |
|---|---|---|
| Dry electronics shop | IP40 bare module | Grease twice a year |
| General machining | IP54 basic seals | Quarterly greasing |
| Grinding, textile dust | IP65 plus bellows | Monthly blow-out check |
| Wet chips, coolant | IP67 stainless parts | Weekly visual, monthly grease |
| Outdoor, sheltered | IP65 plus rain hood | Monthly full check |
| Cleanroom | IP40 low-dust grease | Per cleanroom rules |
Specify the IP rating and bellows at quotation; retrofitting later costs two to three times more plus downtime. Inspect seal assembly before first power-up; a skewed seal equals no seal.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Ingress ratings follow GB/T 4208 (identical to IEC 60529); electrical installation follows GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.