A stepper that buzzes and loses steps at certain speeds has hit its resonance band. This page explains the cause, how to find the dangerous speeds, and six ways around them.
Every step carries a slight overshoot and rebound, giving the motor a natural oscillation like a pendulum, typically 50 to 150 Hz, corresponding to 1 to 3 revolutions per second. When the step frequency approaches this natural frequency, the oscillation grows beat by beat: audible buzz, sharp torque loss, visible jitter and eventual lost steps. For two-phase 1.8 degree motors the danger zone sits near 1 to 2 rps, right where many mechanisms work, which is why resonance keeps showing up.
Three ways to find the band: sweep speed slowly from 0.5 rps and listen for the buzz to swell; feel the housing for fine vibration with accelerating heat; watch line or circle drawing for periodic facets. The band spans about 20 to 30 percent, so a centre at 1.5 rps endangers 1.2 to 1.8 rps. Record each machine band on a label; programming around it beats tuning against it.
Six countermeasures: microstepping at 8 or more cuts torque ripple and halves resonance; sweep through the band without stopping in it; add mechanical or electronic damping such as drive notch filters; use half-step or five-phase motors to push the natural frequency up; keep the inertia ratio between 1 and 3 where resonance is mildest; and raise drive voltage with decay-mode tuning for cleaner current. Combining the first three usually suffices.
| Measure | Effect | Cost |
|---|---|---|
| Microstep 8 or more | Halves resonance | Weakens at high speed |
| Sweep through the band | Free | Dwell points outside band |
| Damping, mech or electronic | Definite | Hardware or drive support |
| Half-step or five-phase | Raises natural frequency | Motor replacement |
| Inertia ratio 1 to 3 | Attacks the root | Decided at sizing |
| Higher voltage, tuned decay | Cleaner current | Slightly more heat |
Sweep every new machine before shipping and write the band into the manual so users can program around it. Resonance is a characteristic, not a fault; training operators beats repeated repair calls.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Vibration limits reference IEC 60034-14; small motor safety follows GB/T 12350; machine electrical safety follows GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.