Stepper lost steps and the resonance zone

A stepper that buzzes and loses steps at certain speeds has hit its resonance band. This page explains the cause, how to find the dangerous speeds, and six ways around them.

1. How it works

Every step carries a slight overshoot and rebound, giving the motor a natural oscillation like a pendulum, typically 50 to 150 Hz, corresponding to 1 to 3 revolutions per second. When the step frequency approaches this natural frequency, the oscillation grows beat by beat: audible buzz, sharp torque loss, visible jitter and eventual lost steps. For two-phase 1.8 degree motors the danger zone sits near 1 to 2 rps, right where many mechanisms work, which is why resonance keeps showing up.

2. Numbers and practice

Three ways to find the band: sweep speed slowly from 0.5 rps and listen for the buzz to swell; feel the housing for fine vibration with accelerating heat; watch line or circle drawing for periodic facets. The band spans about 20 to 30 percent, so a centre at 1.5 rps endangers 1.2 to 1.8 rps. Record each machine band on a label; programming around it beats tuning against it.

3. Pitfalls and fixes

Six countermeasures: microstepping at 8 or more cuts torque ripple and halves resonance; sweep through the band without stopping in it; add mechanical or electronic damping such as drive notch filters; use half-step or five-phase motors to push the natural frequency up; keep the inertia ratio between 1 and 3 where resonance is mildest; and raise drive voltage with decay-mode tuning for cleaner current. Combining the first three usually suffices.

4. Resonance countermeasures quick table

MeasureEffectCost
Microstep 8 or moreHalves resonanceWeakens at high speed
Sweep through the bandFreeDwell points outside band
Damping, mech or electronicDefiniteHardware or drive support
Half-step or five-phaseRaises natural frequencyMotor replacement
Inertia ratio 1 to 3Attacks the rootDecided at sizing
Higher voltage, tuned decayCleaner currentSlightly more heat

5. Notes

Sweep every new machine before shipping and write the band into the manual so users can program around it. Resonance is a characteristic, not a fault; training operators beats repeated repair calls.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Vibration limits reference IEC 60034-14; small motor safety follows GB/T 12350; machine electrical safety follows GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Leaving the duty point inside the resonance band loses steps and scrapes product while cooking the motor
② Masking resonance with microstepping while the dwell point stays in the band keeps end-of-move jitter
③ Chasing resonance with a spanner as if it were loose bolts makes it worse; sweep and locate the band first

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.