An incremental encoder axis forgets where it is at every power cut. This page lays out four solutions from mechanical homing to absolute retrofit, ordered by cost, plus the homing details that decide repeaterability.
Incremental encoders report only change; the count lives in the drive and clears at power-off, so after restart the drive knows the motor did not move but not where the axis stands. Half-closed loops on motor encoders and full-closed loops with incremental scales share this limit. The consequence is a mandatory homing cycle of seconds to tens of seconds, with collision risk during the move. No parameter can remove a principle.
Four options by cost: a mechanical reference stop with Z-pulse zeroing at low speed, cheapest for single axes with a clear approach; a soft reference, writing the last parked position to retained memory before shutdown, valid only if nobody moves the mechanism; battery-backed counting, supported by some drives but noise sensitive, avoid on precision axes; or an absolute motor with battery, permanent but pricey. Evaluate in that order when the budget is tight.
Homing details matter: approach at 1 to 5 mm/s, back off, re-approach slowly, and repeaterability lands within one count. When a limit doubles as the reference block, leave at least 3 mm of deceleration margin. Fix the homing order of multi-axis machines by collision avoidance and lock it in the program, and always fit a homing timeout, 30 seconds, to stop endless block crashing.
| Solution | Cost | Reliability | Fits |
|---|---|---|---|
| Mechanical homing | Lowest | Depends on stop block | Single axis, clear path |
| Soft reference memory | Low | Void if moved after stop | Fixed park position |
| Battery-backed counts | Medium | Noise sensitive | Non-precision axes |
| Absolute motor retrofit | High | Most reliable | Cycle-critical multi-axis |
| Homing speed | 1 to 5 mm/s approach | Slow for accuracy | All incremental axes |
| Homing timeout | 30 seconds alarm | Prevents endless crashing | All incremental axes |
Write into the operating procedure that every power-up must home before automatic start; skipping homing is the most common cause of start-up crashes. When retrofitting, show the customer the homing-time cost; most accept the absolute encoder price once they see the numbers.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Homing functions and safety follow GB/T 5226.1; numerical control systems reference the IEC 61131 series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.