Tuning speed-mode servos for changing loads

When a speed-mode servo slows under load or oscillates, the gains usually do not match the inertia. This page explains how load inertia limits speed-loop gain, the tuning order, and how to verify with load steps.

1. How it works

The ceiling of speed-loop gain is set by the inertia ratio: the larger the ratio, the lower the usable gain. Below roughly 3:1 you can run high stiffness; above 10:1 reduce gain and lengthen acceleration ramps. A sudden load step, such as a clutch engaging, unbalances the loop and shows as a speed dip whose depth shrinks as gain rises. Enter an accurate inertia ratio in the drive first, because most auto-tuning routines depend on it.

2. Practice and pitfalls

Tune in order: current loop (usually fine from the factory), then speed loop, then position loop. Start speed proportional gain at half the default, raise it until slight oscillation, then back off 20 percent. Add integral action, typically 20 to 100 ms, to remove steady-state error. Acceptance: overshoot under 5 percent with recovery within 50 ms on a step, and speed dip below 3 percent on a rated load step.

3. Speed loop tuning quick reference

SymptomLikely causeAction
Speed dip above 3 percentLow speed-loop gainRaise Kp by 10 percent and retest
Oscillation unloaded onlyGain too high for no loadLower gain or switch gain sets
Overshoot above 5 percentIntegral time too shortLengthen integral by 20 percent
Steady-state driftSetpoint ripple or offsetCheck analogue and re-zero
Jitter at end of rampWrong inertia ratioMeasure inertia and re-enter
Sluggish feedbackCoupling slipTighten or replace coupling

4. Notes

Record the inertia ratio, both gain sets and their switching conditions in the tuning report. Revisit weekly for the first two weeks; if speed ripple exceeds 2 percent after a material change, re-verify the parameter set.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Servo tuning practice follows GB/T 5226.1; adjustable-speed drive performance references the IEC 61800 series. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Guessing the inertia ratio corrupts auto-tuning results; measure and enter the real value
② Turning gain without touching integral time leaves steady-state error plus overshoot; tune both together
③ Mistaking coupling slip for low gain invites resonance; check the feedback waveform before raising gain

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.