Injection moulding is the main battlefield of hydraulic servo; retrofitting a servo pump saves 30 to 70 percent of energy. This page covers the retrofit, dual pressure-flow closed loops and injection accuracy.
Traditional machines run a fixed pump plus proportional valves: the motor spins at full speed and surplus flow burns across the relief valve. The servo-pump scheme drives a fixed pump with a permanent-magnet synchronous motor, regulating speed to the demanded pressure and flow in dual closed loops, supplying only what is needed. Measured gains: 50 to 70 percent on parts with long holding and cooling, 30 to 50 percent generally; noise drops from 85 to below 70 dB; oil runs 10 to 15 degrees cooler, doubling oil life. Payback on electricity is typically 1 to 2 years on three shifts.
Both loops close: a pressure sensor feeds back system pressure, an encoder feeds back pump speed, and the controller issues speed commands. Dynamics matter: the flow loop must track the injection speed profile with response inside 50 ms, and the switch from injection to holding must complete within 20 ms or flash and sinks appear. The 2 to 3 times overload capacity of the PMSM reaches rated speed from zero in 0.1 s. Tune the multi-stage injection speed profile to wall thickness and derive holding pressure from shrinkage.
Accuracy targets: injection speed repeaterability within plus-minus 2 percent, holding pressure ripple within plus-minus 0.5 MPa, metering stroke repeaterability within plus-minus 0.1 mm. Speed variation shows as weld lines and burns; holding variation as sinks and flash. The retrofit keeps valves and cylinders, changing only the power pack and controls over 3 to 5 days. Verify low-speed stability: below 300 rpm flow pulsation shows, so screen pumps on low-speed behaviour. Keep oil cleanliness at NAS class 9 for the valves.
| Item | Before | After | Gain |
|---|---|---|---|
| Energy | Fixed pump, relief loss | On-demand supply | 30 to 70 percent saved |
| Noise | About 85 dB | Below 70 dB | Better shop floor |
| Oil temperature | 55 to 65 degrees C | Within 45 degrees C | Oil life doubled |
| Pressure switch | Over 100 ms | Within 20 ms | Less flash and sink |
| Payback | None | 1 to 2 years | Three-shift basis |
| Retrofit time | None | 3 to 5 days | Power pack swap |
Take a one-week power baseline before the retrofit and compare on identical parts afterwards; the data is what convinces management. Inspect cylinder leakage and valve wear first, or the new pump money leaks into old hydraulics.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Machine safety follows GB 22530 and GB/T 5226.1; hydraulics follow GB/T 3766; drive performance references the IEC 61800 series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.