A perfect motor is useless if the flange does not match. This page explains common flange sizes, IMB mounting designations, shaft and keyway standards, and the five dimensions to lock before drawing the interface.
Servo frames divide by flange size: 40, 60, 80 and 130 being common, with pilot diameters and bolt circles per convention: 40 flange typically 4 times M4, 60 uses 4 times M5, 80 uses 4 times M6, and 130 uses 4 to 6 times M8. IMB5 means a flange-mounted motor without feet, IMB14 a small-flange version with a shallow pilot, IMB35 combining feet and flange. Draw the interface from the manufacturer dimensional page; GB/T 4772 and IEC 60072 describe the convention for rotating machine mounting dimensions.
Shafts are usually cylindrical with a key; high-end models offer D-shafts or hollow shafts. Typical shaft diameters: about 8 to 11 mm on frame 40, 14 to 19 on 60, 22 to 28 on 80 and 32 to 42 on 130, always per the datasheet. Keyways pair with GB/T 1096 parallel keys; bore couplings H7, use a transition fit with set screws, and add a clamp ring for high torque. Dusty duty calls for the shaft-seal version, with the seal position on the interface drawing.
Before releasing the interface drawing, pull the 3D model and dimension table and fill in five items: pilot diameter, bolt circle, shaft diameter, shoulder distance and cable exit direction. Verify incoming motors on all five: pilot by two-point caliper average, threads with a gauge, shaft by micrometer across two directions. Do not assume the same frame number means interchangeable; a 0.2 mm pilot difference either will not fit or runs out of true. Brake projection and centre holes also affect bracket design.
| Frame | Common bolts | Shaft range | Typical duty |
|---|---|---|---|
| 40 | 4 times M4 | 8 to 11 mm | Light conveying, indexing |
| 60 | 4 times M5 | 14 to 19 mm | General handling |
| 80 | 4 times M6 | 22 to 28 mm | Machine auxiliary axes |
| 130 | 4 to 6 times M8 | 32 to 42 mm | Heavy main drives |
| IMB5 | Flange with pilot | Per frame | Standard flange mount |
| IMB14 | Small shallow flange | Per frame | Compact installations |
Lock the motor brand and frame at interface-drawing stage; later brand swaps rarely share flanges. Verify mounting dimensions at goods-in and claim within warranty; discovering a mismatch after installation guarantees a dispute.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Mounting dimensions follow GB/T 4772 and the IEC 60072 series; keyways follow GB/T 1096 and GB/T 1095; electrical safety follows GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.