Semi-closed loops cannot see ball screw backlash or thermal drift; a full-closed loop with an absolute linear scale can. This page covers installation, wiring, gain adjustment and compensation details.
A semi-closed loop feeds back only the motor encoder, leaving screw backlash, pitch error and thermal drift outside the loop, with typical accuracy of 0.02 to 0.05 mm. A full-closed loop measures the table directly with a linear scale mounted on the slide, pulling those errors inside the loop for accuracy within 0.005 mm. The price is extra mechanical resonance in the loop, so gains drop a notch. Absolute scales keep position through power cuts, eliminating homing after every restart.
Installation rules: keep the scale rail parallel to the guideway within 0.02 mm/m; maintain the reading head gap per the manual, typically 0.8 to 1.5 mm, without scraping along the stroke; mount close to the load path and away from screw heat. Use double-shielded dedicated cable in a separate tray; beyond the manual length limit, commonly 20 to 50 m, add a repeater. Fit the battery box on a dry machine face away from coolant spray and check its voltage every six months.
Commissioning: tune gains in semi-closed mode first, then switch to full-closed starting at 60 percent of the position gain and raise until stable. Measure backlash with a laser interferometer or ballbar and compensate in 5 to 10 segments rather than one value. Quadrant bumps and crawling usually trace to guideway friction or backlash; fix the mechanics before chasing parameters, and redo pitch compensation because the old semi-closed table over-compensates.
| Item | Semi-closed | Full-closed |
|---|---|---|
| Feedback element | Motor encoder | Scale on slide |
| Typical accuracy | 0.02 to 0.05 mm | Within 0.005 mm |
| Loop character | Resonance outside loop | Resonance inside, lower gain |
| Position after power cut | Depends on encoder | Absolute scale retains it |
| Commissioning order | Direct tuning | Tune semi-closed first, then switch |
| Compensation tables | Calibrate once | Redo under full-closed |
Measure semi-closed accuracy before upgrading; with backlash above 0.01 mm a full-closed loop wastes money, so fix the mechanics first. For travels beyond 3 m confirm the jointing process and seam accuracy of the scale.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Position detection and accuracy practice reference GB/T 5226.1 and IEC 61491 digital interface standards. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.