Half of servo overheating alarms are electrical, half are mechanical or cooling related. This page gives a search order: load ratio first, cooling next, the motor itself last.
Overheat alarms come by two paths: the drive software model estimating winding temperature, tripping near 140 degrees C, and the hard sensor, a thermistor or thermal switch in the motor, tripping at 80 to 120 degrees C. Read the drive load ratio and estimated temperature first: a load ratio persistently above 80 percent means undersizing; a high estimate without a sensor trip suggests model drift; a sensor trip with a low estimate points at sensor wiring or connectors. Both maxed out means genuine overheating.
Load-side causes: acceleration too aggressive, keeping peak torque above 80 percent of motor maximum; mechanical sticking raising friction, suspected when no-load current runs 20 percent above normal; and high gains causing high-frequency heating, felt as a fine buzz on the housing. Cooling-side causes: ambient above 40 degrees C without derating, heat surface fouled with oil and dust, high thermal resistance mounting, and brake drag from a too-tight brake gap.
Three field checks: an IR gun on the housing, above 90 degrees C is real heat; a clamp meter against nameplate current, above 90 percent persistent is overload; and no-load versus loaded current difference, a small gap indicates friction loss. Fix order: clean cooling surfaces, widen ramps 20 percent, drop stiffness three to five levels, then upsize the motor. Frequent jog and reversing duty needs S3 duty checking, never S1.
| Check item | Normal range | Action if out of range |
|---|---|---|
| Drive load ratio | Below 80 percent | Upsize motor or slow cycle |
| Housing temperature | Below 90 degrees C | Clean cooling, check load |
| Current versus rating | Below 90 percent | Inspect mechanical sticking |
| No-load current versus normal | Within 10 percent | Check friction and assembly |
| Ambient temperature | Below 40 degrees C | Derate above it |
| Accel torque | Below 80 percent of max | Lengthen ramps |
Log load ratio, current and ambient temperature at every overheat event; three months of records separate a sizing problem from a degradation problem. Blow down cooling surfaces before the hot season to clear most seasonal alarms.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Temperature limits follow GB/T 12350 for small motors and IEC 60034-1 temperature-rise classes; machine safety aligns with GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.