Pulse servos are cheap, EtherCAT costs more; where does the money go? This page compares synchronisation, diagnostics, wiring and cost, then advises by axis count and cycle demands.
Pulse control inherits the host scan cycle, so multiple axes share no hard synchronisation and inter-axis deviation wanders, visible as poor circle roundness in high-speed interpolation. EtherCAT uses distributed clocks with sync error under 1 microsecond and cycles of 125 to 500 microseconds; the interpolation quality is measurable. For single-axis point moves the two are equivalent; from three interpolated axes upward the bus wins immediately. Pulse rates top out around 100 kpps to 4 Mpps differential, while bus bandwidth barely degrades with axis count.
Diagnostics and wiring: the bus exposes per-axis torque, position, temperature and alarms live at the master with timestamps, while pulse control offers IO levels and the drive panel. Wiring drops from three to five shielded wires per axis to one shared network cable. Pulse hardware runs 20 to 30 percent cheaper, but labour and cabinet space reverse that; beyond eight axes the bus usually costs less overall.
Guidance: under four axes of point-to-point duty, pulses are fine and cheap; eight axes or any camming, synchronisation or pressure-displacement profiling, go EtherCAT. Migration needs a PLC with an EtherCAT master and the drive device descriptions imported, with the distributed clock configured. Mixed architectures work: interpolated axes on the bus, simple feeders on pulses through a gateway, but budget the dual toolchains for maintenance.
| Aspect | Pulse servo | EtherCAT servo |
|---|---|---|
| Multi-axis sync | None | Error under 1 microsecond |
| Control cycle | Scan limited | 125 to 500 microseconds |
| Wiring per axis | 3 to 5 shielded wires | One shared cable |
| Diagnostics | IO and panel | Full live parameters |
| Hardware cost | 20 to 30 percent lower | Wins above eight axes |
| Best scale | Under 4 axes, point moves | 8 plus axes, interpolation |
Price wiring labour, cabinet volume and diagnostics into both options before comparing; the hardware gap shrinks on site. For new multi-axis lines go straight to the bus; for retrofitting old equipment keep the pulses.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Real-time Ethernet and fieldbus profiles follow IEC 61784 and IEC 61158; electrical safety follows GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.