Cylinders are the cheapest actuators, but guessing the bore means stalls or crushed tooling. This page covers single versus double acting, bore and thrust calculation, cushioning and switch fitting.
The principle is pressure times piston area. Double-acting cylinders feed both sides, push and pull with control, and dominate; single-acting ones return by spring, push only, and suit clamp-and-hold duty. Bore series: 12 to 100 mm. Thrust follows F = P times pi D squared over 4; at 0.5 MPa a 40 mm bore gives about 628 N theoretical, derated to roughly 500 N practical, with the pull side about 85 percent of push.
Bore selection in three steps: compute the load force, apply a load ratio of 0.5 to 0.7 horizontal or 0.3 to 0.5 vertical, then back-solve the bore. Example: lifting 20 kg vertically needs 196 N; at a 0.4 ratio that is 490 N theoretical, which back-solves to D = 35.4 mm at 0.5 MPa, so choose the standard 40 mm bore. Keep the ratio below 0.7 so supply fluctuation cannot stall the cylinder.
Cushioning: any end speed above 0.3 m/s needs a cushion; adjustable needle valves tuned until the bang disappears; heavy fast loads deserve external hydraulic shock absorbers, five times the life of air cushions. Magnetic switches on the barrel detect piston ring position; match NPN or PNP to the PLC input and thread-lock the fixing screws against vibration. Air preparation, filter-regulator-lubricator at 5 µm, is mandatory; dirty air is what kills seals.
| Bore mm | Theoretical thrust at 0.5 MPa | Practical, about | Typical duty |
|---|---|---|---|
| 20 | 157 N | 120 N | Light clamping |
| 32 | 402 N | 300 N | General pushing |
| 40 | 628 N | 500 N | Common handling |
| 63 | 1559 N | 1200 N | Heavy pushing |
| 80 | 2513 N | 2000 N | Pressing, ejection |
| 100 | 3927 N | 3000 N | High-force duty |
Tape the thrust table inside the air cabinet and pick bores on the spot within one step. Hand-cycle every new cylinder and listen to the cushion before fitting; a dead cushion is a crash waiting to happen.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Pneumatic installation and safety follow GB/T 5226.1; cylinder products reference GB/T 24978 and actuator safety under IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.