Inertia ratio unit conversion for servo sizing

Mixing kg·m², kg·cm² and GD² units is a classic way to wreck an inertia calculation. This page gives the conversions, the estimation formulas for common parts, and quick checks used on the shop floor.

1. How it works

Three unit systems appear in practice: SI kg·m², engineering kg·cm², and the legacy flywheel moment GD² in kgf·m². The relations are 1 kg·m² = 10000 kg·cm² and J = GD² divided by 4g with g = 9.81 m/s², so divide GD² by 39.24 to get J. Convert everything to kg·m² before combining, and keep numerator and denominator consistent when forming the ratio. Treating kg·cm² as kg·m² inflates the ratio ten-thousand-fold.

2. Numbers and practice

Handy formulas: solid cylinder J = m times D squared over 8; hollow cylinder J = m times (D squared minus d squared) over 8; a translating mass on a screw reflects as J = m times P squared over 4 pi squared with lead P in metres; pulley inertias multiply by the square of the reduction ratio. Compare the sum with the rotor inertia from the manual, for example about 1.3 times ten to the minus 4 kg·m² for a 750 W motor.

3. Pitfalls and fixes

For quick estimates, take the radius of gyration as 0.7 of the outer radius for discs and 0.5 for long shafts; 20 percent accuracy is enough. Cross-check with the drive identification routine and investigate any deviation above 30 percent, usually a missed gearbox ratio or a unit slip. List every part including couplings and fixtures, which together can reach 30 percent on small motors.

4. Inertia unit conversion quick table

Unit or objectConversion or formulaShop note
kg·m² to kg·cm²Multiply by 10000Do not reverse it
GD² to JDivide by 39.24Legacy drawings trap
Solid cylinderJ = m times D² over 8Couplings, rollers
Moving load on screwJ = m times P² over 4π²Lead in metres
Pulley reflectionMultiply by ratio squaredMissing it multiplies error
750 W rotor inertiaAbout 1.3e-4 kg·m²Confirm from manual

5. Notes

Make a part list and unify units on paper before computing the ratio; ten minutes here saves hours of tuning. Keep the reduction-ratio squaring on its own line and reconcile the hand value against drive identification, investigating deviations beyond 30 percent.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Motor inertia and performance data follow IEC 60034; general sizing practice aligns with GB/T 5226.1 documentation. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Substituting kg·cm² for kg·m² inflates the ratio ten-thousand-fold and wrecks tuning completely
② Forgetting to square the reduction ratio understates inertia dozens of times and hides usable gain
③ Omitting couplings and fixtures misses up to 30 percent of inertia on small motors, so hand values never match identification

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.