With an inertia ratio of 30 to 50 the loop rings no matter how you tune. This page covers the compensation paths: adding a gearbox, upsizing the motor, softening the ramps and segmented positioning, with their cost and cycle trade-offs.
Before compensating, recheck the inertia: many large ratios come from reflection errors, such as forgetting to square the reduction ratio or misjudging the workpiece radius. For a direct screw use J = m times P squared over four pi squared; sum every pulley and disc term. Ratios of 30 to 50 are borderline and yield to parameters; above 80 usually needs structural change. The test: if positioning still meets the cycle at the highest non-ringing stiffness, parameters can save it.
Four paths, in cost order: a gearbox divides reflected inertia by the square of the ratio, turning 50 into 2 with a 1:5 unit, at the price of cost, backlash and space. A larger motor raises rotor inertia but forces a drive and cable change. Softening means lower stiffness and 20 to 50 percent longer ramps: free but slower. Segmented positioning runs the stroke fast then creeps the last section, costing less cycle time than slowing everything. A torque filter near the resonance frequency buys another three to five stiffness levels. Change one thing at a time and step-test after each, overshoot under 5 percent.
| Path | Effect | Cost |
|---|---|---|
| Add gearbox | Divide inertia by ratio squared | Cost, space, backlash |
| Upsize motor | Larger rotor lowers ratio | Drive and cables replaced |
| Softened ramps | Stable but sluggish | Cycle time up 20 to 50 percent |
| Segmented positioning | Fast then creep | Small program change |
| Torque filter | Three to five stiffness levels back | Wrong band makes it worse |
| Recheck reflection | Excludes false large ratios | Free, do it first |
Recheck before restructuring: more than half of large-ratio problems are calculation errors. Put cycle impact and retrofit cost on the table at design review rather than bolting on a gearbox on a hunch.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Selection and tuning follow GB/T 5226.1; motor and drive matching references IEC 60034 and the IEC 61800 series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.