Displacement and flow are the two core parameters in hydraulic pump selection, and many beginners confuse them. Displacement V is the oil volume the pump delivers per revolution (mL/r), an intrinsic pump property; flow q is the oil volume delivered per unit time (L/min), determined jointly by displacement, speed, and volumetric efficiency. Using a system that requires 40 L/min, the following covers displacement calculation, model selection, and motor power all at once.
Required system flow q = 40 L/min, pump speed n = 1450 r/min (4-pole motor),
Volumetric efficiency ηv = 0.92 (gear pump), working pressure p = 16 MPa, overall efficiency η = 0.85.
Find: pump displacement V, standard model, and motor power.
Note: divide the required flow by the volumetric efficiency; the displacement must leave a margin for volumetric losses.
The CB-B series is the most common low-pressure gear pump series in China; its displacement sizes are 10/16/20/25/32/40/50…, and we round up to 32.
Actual flow 42.7 L/min ≥ required 40 L/min ✓ meets the requirement, with a 6.7% margin.
In the formula p is in MPa and q in L/min. Input power = hydraulic power / overall efficiency. Select the standard motor 15 kW (4-pole).
If calculated by theoretical flow: V = 40×1000/1450 = 27.6 mL/r, select CB-B25.
Actual flow q = 25×1450×0.92/1000 ≈ 33.4 L/min < 40 L/min ✗ Insufficient flow!
All actuator speeds fall short of the design values; the displacement must be corrected by the volumetric efficiency.
| Type | Displacement variable? | Volumetric efficiency ηv | Pressure range | Applications |
|---|---|---|---|---|
| Gear pump | Fixed displacement | 0.90 ~ 0.95 | ≤ 25 MPa | General industry, construction machinery |
| Vane pump | Fixed/variable | 0.85 ~ 0.92 | ≤ 21 MPa | Machine tools, injection molding machines |
| Axial piston pump | Fixed/variable | 0.92 ~ 0.98 | ≤ 35 MPa | Heavy-duty, high-pressure precision systems |
| Screw pump | Fixed displacement | 0.90 ~ 0.95 | ≤ 10 MPa | Conveying, lubrication systems |
| Parameter | Symbol | Definition | Unit |
|---|---|---|---|
| Displacement | V | Oil volume the pump delivers per revolution | mL/r |
| Theoretical flow | q_t | V × n / 1000, no leakage loss | L/min |
| Actual flow | q | q_t × ηv, deducting volumetric loss | L/min |
| Speed | n | Pump drive speed | r/min |
1. Theoretical flow:
2. Actual Flow:
3. Displacement from Known Flow:
4. Motor Input Power:
| Symbol | Meaning | Unit | Value notes |
|---|---|---|---|
| V | Pump displacement | mL/r | Intrinsic pump parameter, for model selection |
| n | Speed | r/min | 4-pole motor around 1450 |
| ηv | Volumetric efficiency | — | Gear pump 0.9~0.95 |
| η | Overall efficiency | — | ηv × mechanical efficiency, 0.8~0.9 |
| p | Working pressure | MPa | System max pressure |
| q | Actual flow | L/min | Determines actuator speed |
| Spec | Displacement mL/r | Rated pressure MPa | Actual flow at 1450r/min (ηv=0.92) |
|---|---|---|---|
| CB-B25 | 25 | 16 | ≈ 33.4 L/min |
| CB-B32 | 32 | 16 | ≈ 42.7 L/min |
| CB-B40 | 40 | 16 | ≈ 53.4 L/min |
| CB-B50 | 50 | 16 | ≈ 66.7 L/min |
| # | Common error | Consequence | Correct approach |
|---|---|---|---|
| 1 | Confusing displacement with flow | Large pump selection error | Distinguish V(mL/r) from q(L/min) |
| 2 | Ignore volumetric efficiency | Actual flow insufficient | V = q×1000/(n·ηv) |
| 3 | Not dividing motor power by overall efficiency | Motor overload burnout | P = p·q/(600·η) |
| 4 | Wrong speed used | Large flow deviation | Calculate by the actual drive speed |
| 5 | Round displacement down | Insufficient flow, speed below target | Round up to the standard specification |