The relief valve is the "safety valve" of a hydraulic system. If the set pressure is too high, overpressure goes unprotected; if too low, the system pressure cannot build up and heat is generated. It serves both as a pressure-regulating and an overload-protection device, and involves overflow flow, power loss, and pressure fluctuation. Using a fixed-displacement pump throttling speed-control system as an example, the following works through pressure setting, overflow, and stability in one pass.
Fixed-displacement pump supply q_p = 40 L/min; through throttling speed control, the actuator actually needs q_1 = 25 L/min.
Maximum system working pressure p = 12 MPa; a pilot-operated relief valve is used as the pressure-regulating overflow valve (also serving as safety protection).
Find: set pressure p_k, overflow flow q_y, and overflow power loss P_y.
As a pressure-regulating overflow valve, the set pressure should be 0.5~1 MPa above the system working pressure (0.8 here), leaving a pressure margin for valve opening to prevent frequent cycling during normal operation.
In a throttling speed-control circuit, all excess pump flow returns to the tank through the relief valve. The overflow flow is 15 L/min, accounting for 37.5% of total supply.
This power is entirely converted into oil heating and is the main reason for the low efficiency of throttling speed-control systems. The larger P_y, the greater the heat-dissipation load on the tank.
At a set pressure of 13 MPa, fluctuation should be kept within ±0.2 MPa. If fluctuation exceeds tolerance or screaming occurs, check whether the pilot-valve damping orifice is clogged, whether the pressure-adjusting spring resonates, and whether the oil is aerated.
Set p_k = 12 MPa (equal to the working pressure): any slight load fluctuation makes the relief valve open frequently, causing large pressure fluctuation, system shock, and rapid spool wear ✗.
Set p_k = 15 MPa (too high): under normal conditions it does not overflow, seemingly saving oil, but once the equipment is overpressured, pressure spikes to 15 MPa before the valve opens, so protection lags and components are overloaded ✗.
→ Set 13 MPa; under normal conditions it cracks slightly to balance flow, and on overpressure opens fully at once, balancing pressure regulation and protection ✓.
| Type | Structure | Pressure ripple | Adjustment range | Application |
|---|---|---|---|---|
| Direct-acting | Spool pressed directly by spring | Around ±0.5 MPa | Small flow | Low pressure, small flow, safety valve |
| Pilot-operated | Pilot valve + main valve, two stages | Within ±0.2 MPa | Large flow | Pressure-regulating overflow, high pressure and large flow |
| Solenoid relief valve | Pilot-operated + solenoid valve | Within ±0.2 MPa | Can unload | Multi-stage pressure adjustment, unloading circuit |
1. Set pressure (pressure-regulating overflow):
2. Set pressure (safety protection):
3. Overflow flow:
4. Overflow power loss (heat generation):
| Symbol | Meaning | Unit | Value notes |
|---|---|---|---|
| p_k | Set pressure | MPa | Select the 0.5~1 or 1.05~1.1 coefficient by purpose |
| p_work | System working pressure | MPa | Maximum working pressure of the actuator |
| q_y | Overflow flow | L/min | Pump flow minus system required flow |
| P_y | Overflow power loss | kW | Converted into oil heating |
| Ripple | Pressure fluctuation range | MPa | Pilot-operated ≤ ±0.2, direct-acting ≤ ±0.5 |
| Relief valve use | Set pressure | Notes |
|---|---|---|
| Throttling pressure regulation | p_work + 0.5~1 MPa | Ensure stable system pressure |
| System safety valve | 1.05~1.1 × p_max | Prevent overload, leave margin |
| Multi-stage pressure setting | Set pressures separately for each operating condition | Switch with a solenoid relief valve |
| Back-pressure valve | 0.3~0.8 MPa | Stabilize actuator motion |
| # | Common error | Consequence | Correct approach |
|---|---|---|---|
| 1 | Set pressure equal to working pressure | Frequent cycling, large fluctuation | For pressure regulation use p+0.5~1 MPa |
| 2 | Set pressure too high | Overpressure protection lags, components overloaded | For safety valve use 1.05~1.1 p_max |
| 3 | Ignore overflow power loss | Tank overheating, oil temperature exceeds limit | P_y = p·q_y/60, count it in heat dissipation |
| 4 | For small-flow systems select direct-acting | Large fluctuation, unstable pressure | Use pilot-operated |
| 5 | Remote pressure-adjustment line too long | System oscillation squeal | Use a short, large line and add damping |