Vacuum handling is the most common automated pick-and-place method, but getting the cup force wrong or undersizing the generator means weak grip at best and dropped, smashed parts at worst. The calculation boils down to three points: cup diameter is back-calculated from 'weight × safety factor ÷ vacuum level', and the generator is judged by 'can its pumping rate hold back leakage, and is evacuation time within the cycle'. Using a 10 kg carton-handling line, we run through vacuum-component selection.
A palletizing station horizontally lifts cartons: total mass of workpiece + gripper m=10 kg; 4 vacuum cups are used with a horizontal-lift safety factor S=4; generator working vacuum −60 kPa (economical range); supply pressure 0.5 MPa; cup-to-generator line length 8 m, inner diameter 6 mm; target evacuation time t=0.6 s.
Find: cup diameter, vacuum-generator model, and verify evacuation time.
The horizontal-lift safety factor is 4 (vertical lifting requires 8). If acceleration/deceleration is significant, use the dynamic form F=m·(g+a)·S for safety.
Δp is the vacuum differential; −60 kPa means 60 kPa = 60000 Pa. The calculated diameter is 45.6 mm; round up to the standard series: choose four φ50 mm flat-type NBR (nitrile) cups.
Actual force per cup is 118 N, 20% above demand; the actual safety factor S≈4.8, acceptable ✓. Note: always round cup diameter up to the standard size; don't drop to the next smaller size just to save material.
Effective volume per cup after deformation is estimated as A×h≈1963×8 mm³ (h ≈ 8 mm cup compression height); four cups ≈ 0.063 L; an 8 m line of φ6 inner diameter ≈ 0.226 L; total ≈ 0.29 L. The longer and wider the line, the larger this number.
−60 kPa corresponds to absolute pressure P₁=101.3−60=41.3 kPa, ln(P₀/P₁)=ln2.45≈0.897. To reach target vacuum in 0.6 s, the generator's pumping rate at that vacuum must be at least 26 L/min.
At 0.5 MPa supply, a 1.0 mm-nozzle generator gives ≈ 28 L/min at −60 kPa, meeting the 26 L/min need; if the cycle is tighter or the line longer, step up to a 1.5 mm nozzle (≈ 60 L/min). Its 80 L/min supply air counts toward compressor load (≈ 40 L/min at 50% duty). Circuit fittings: vacuum filter (5 µm, prevents dust clogging the nozzle), vacuum break valve (fast release for part drop), vacuum pressure switch (alarms below −60 kPa to prevent drops), and silencer ✓.
Corrugated cartons are breathable; surface leakage can reach 20~40 L/min. Using the same 1.0 mm generator, leakage exceeds its 28 L/min pumping rate, pulling equilibrium vacuum down to about −30 kPa—only half the force—and parts drop the moment you accelerate ✗.
→ For breathable/porous workpieces don't fight it with a standard generator; use a high-flow generator, a vacuum pump, or a leakage-compensated circuit ✓.
| Comparison item | Vacuum generator | Vacuum pump |
|---|---|---|
| Principle | Compressed air throttled through a nozzle creates vacuum | Motor-driven mechanical pump evacuates |
| Application | Single point / low flow, intermittent gripping | Centralized multi-cup, high continuous flow, high vacuum |
| Suction speed/vacuum | Low pumping rate, economical vacuum −60~70 kPa | High pumping rate, up to −85~95 kPa |
| Features | No moving parts, compact, flexible mounting, consumes air | Efficient but heavy, costly, needs power supply |
Cup → vacuum filter → vacuum generator → (supply side) solenoid valve / pressure regulator; vacuum break valve parallel at the cup side; pressure switch detects the grip-confirm signal and inhibits robot motion when grip is insufficient.
1. Theoretical suction force (per cup):
2. Required force including safety factor:
3. Evacuation time / required pumping rate:
4. Back-calculate effective cup diameter:
| Symbol | Meaning | Unit | Value notes |
|---|---|---|---|
| m | Workpiece + gripper mass | kg | Includes cups, lines, and other moving mass |
| S | Safety factor | — | Horizontal 4, vertical 8; higher for large acceleration |
| p_v | Vacuum level | Pa/kPa | Generator −60~70; vacuum pump −85~95 |
| n | Cup count | pcs | ≥3 to prevent eccentric load tipping |
| V | Total evacuation volume | L | Cup effective volume + line volume |
| q | Generator pumping rate (at the given vacuum) | L/min | Read from the catalog curve, not the max pumping rate |
| Nozzle diameter | Max vacuum | Pumping rate at −60 kPa | Air consumption | Typical use |
|---|---|---|---|---|
| φ0.5mm | −90kPa | ≈8 L/min | ≈20 L/min | Light load, small cups (≤2 kg) |
| φ0.7mm | −90kPa | ≈14 L/min | ≈40 L/min | Small fixture |
| φ1.0mm | −90kPa | ≈28 L/min | ≈80 L/min | Small/medium handling (used in the example) |
| φ1.5mm | −90kPa | ≈60 L/min | ≈170 L/min | Large cups / multi-cup fast cycle |
| # | Common error | Consequence | Correct approach |
|---|---|---|---|
| 1 | Safety factor of 2 or even omitted | Parts drop and smash workpieces under acceleration/vibration | Horizontal S=4, vertical S=8 |
| 2 | Calculated diameter 45.6 rounded down to φ40 | Insufficient force, failure at boundary conditions | Round up to φ50 in the standard series |
| 3 | Ignoring acceleration/deceleration inertia | Workpiece drops at high-speed start/stop | Dynamic check F=m(g+a)S |
| 4 | Using a standard generator for breathable/porous parts | Leakage > pumping rate, vacuum pulled down, part drops | High-flow generator / vacuum pump / leakage compensation |
| 5 | Long thin lines, no evacuation-time check | Slow grip, cannot keep up with the cycle | Check q=V·ln(P₀/P₁)/t |
| 6 | Circuit has no filter or pressure switch | Nozzle clogged, no alarm on loss of vacuum | 5 µm filter + vacuum-switch interlock |