E41-002 · Motor Selection · SCARA Robot Z-Axis · ★★★
During high-speed point-to-point positioning of the robot, the Z-axis end effector oscillated continuously; the settling time exceeded 500ms and it could not converge into the ±0.01mm accuracy band. Oscilloscope observation of the velocity curve showed 3~4 repeated overshoot/undershoot crossings near the target position before stabilising, and obvious ripple appeared in the machining trajectory.
The measured load inertia ratio reached 18:1, far beyond the 10:1 limit recommended for servo motors. The motor rotor inertia is 0.0002kg·m² and the total inertia of the lifting mechanism plus the arm is 0.0036kg·m². The system resonance frequency is fs=1/(2π)×√(K/J)=28Hz, close to the natural frequency of the mechanical structure, so the velocity loop and position loop gains could no longer be increased and PID regulation failed.
1) Measure the actual load inertia precisely with an inertia tester or by calculation
2) The inertia ratio should be ≤10:1 (≤5:1 is better for precision applications)
3) Add a gearbox (e.g. i=3:1) so that the converted inertia ratio J_load/(i²×J_motor) meets the requirement
4) Re-tune the servo parameters: velocity loop gain first → then position loop gain → finally feed-forward compensation
5) If the mechanical structure stiffness is insufficient, reinforce it before tuning