E41-083 · Screw Selection · Precision Grinder Wheel-Dresser · ★★★★
Dresser positioning accuracy 0.002 mm; in actual operation an elastic displacement of 0.008 mm occurs in the grinding-force direction. Workpiece dimensions scatter, and CPK drops from 1.33 to 0.8.
The screw fixed-end bearing housing used a cantilever structure (housing mounted on a 12 mm steel plate with 80 mm overhang). During grinding an axial force F_a=600 N acts on the housing; the cantilever-end deflection δ=F×L³/(3×E×I)=600×80³/(3×206000×100×12³/12)=600×512000/(3×206000×17280)=307200000/10679040000≈0.029 mm=29 μm. Guide friction and nut rigidity account for ~40%, the housing cantilever deformation for ~60%. The actual total elastic deformation is about 0.008 mm (29 μm×0.6×system-stiffness coupling factor≈17 μm); the calculation 29 μm×0.6≈17 μm but the actual test was 8 μm, indicating the stiffness analysis is conservative — yet 8 μm still far exceeds the 2 μm requirement.
① Improve bearing-housing structure: eliminate the cantilever design, use double-sided support (a box structure)
② Thicken the mounting plate: 12 mm → 25 mm (rigidity ×8)
③ Add stiffeners: weld two T-section ribs (40 mm high, 10 mm thick) on the back of the housing
④ Use high-rigidity angular-contact bearings: 7206C → paired 72-series, axial rigidity +30%
⑤ Post-installation check: measure bearing-housing axial displacement under max axial force with a dial indicator, ≤0.001 mm
FT_11 Ball Screw Selection