Knowledge Base › Selection Error Cases › Screw-end thread undercut stress concentration causes fracture (vertically installed screw)

Screw-end thread undercut stress concentration causes fracture (vertically installed screw)

E41-122 · Screw Selection · Vertically Installed Lifting Screw · ★★★★

Problem Description

A vertically installed lifting screw fractured at the end thread undercut after about 8 months of use, and the lifting platform fell. The fracture showed clear fatigue striations.

Root Cause

At the screw end-to-bearing-housing connection there is an undercut (R0.2 mm sharp corner) with a stress-concentration factor Kt≈3.8 (sharp undercut). The screw carries an axial tensile force F=5000 N (platform self-weight + load); the nominal stress at the undercut σ_nom=F/A=5000/(π×0.01²)=15.9 MPa, peak stress σ_peak=Kt×σ_nom=3.8×15.9=60.4 MPa. The 60Si2MnA spring-steel fatigue limit σ-1≈350 MPa seems to give a 5.8× safety margin. But in vertical installation the screw bears alternating stress (platform up→down cycle), about 200×/day. Worse, the lift guide is not parallel to the screw (0.1 mm deviation), producing an additional bending stress σ_bend=M/W=(5000×0.1/2)/(π×0.01³/32)=2500/3.93e-7≈6.4 GPa? Calculation error. Correct: σ_bend=F×e×32/(π×d³)=5000×0.05×32/(3.14×0.02³)=8000/2.51e-5=319 MPa. Total peak stress σ_total=60.4+319=379 MPa>350 MPa fatigue limit, causing fatigue fracture after about 50,000 cycles (8 months≈200/day×240 days≈48,000).

Corrective Solution

① Undercut design: sharp corner R0.2 → large fillet R≥2 mm (Kt drops from 3.8 to 1.5)
② Or eliminate the undercut and use a rolled-formed thread (no stress concentration)
③ Improve vertical-installation accuracy: guide-to-screw parallelism ≤0.02 mm
④ Upgrade screw material: 60Si2MnA → 40CrNiMoA (fatigue limit +30%)
⑤ Fit an anti-fall safety device (safety clamp or steel cable)

Checklist

Reference

FT_11 Ball Screw Selection

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »