E41-343 · Screw Selection · Centralized Screw Lubrication Clogging · ★★★
After 3 years of operation all four screw feed-oil lines of the centralized lubrication system were clogged, and the screw nuts ran dry and wore. Teardown found the grease inside the lines had dried and solidified.
The centralized lubrication system used No. 2 lithium grease, with Φ4mm×1mm copper feed lines. The system auto-injects grease every 4h (about 0.5ml per point each time). But the grease base oil gradually evaporated under prolonged high temperature (bearing heat rise → grease in the lines reached about 60℃), at an evaporation rate of about 2%/month. After 3 years about 72% of the base oil had evaporated; the grease thickened and hardened, eventually forming a ~0.5mm layer of dry grease scale on the pipe wall. The internal diameter shrank from Φ4mm to Φ3mm (flow area reduced 44%). The auto-injection pressure (about 20MPa) could still push grease at the start of clogging, but as clogging worsened some branches (the highest-resistance ones) could no longer be fed. The screw on that branch wore from oil starvation, and its backlash grew from 0.005mm to 0.03mm.
① Clean the centralized-lubrication lines every 2 years (flushing oil + compressed-air purge)\n② Use a long-life grease (synthetic hydrocarbon base, base-oil evaporation ≤0.5%/month)\n③ Fit each branch with a flow indicator (to observe grease flow)\n④ Increase line diameter: Φ4→Φ6mm (greater clogging tolerance)\n⑤ Or switch to oil (not grease, no drying risk)
FT_11 Ball Screw Selection