E41-510 · Ball Screw Selection · Loose Coupling Taper Fit on the Ball Screw Shaft End · ★★★
The ball screw shaft end and the coupling were joined by a taper fit (1:10 taper). After repair the coupling became loose on the shaft, producing about 0.1mm of axial wander during running.
The coupling taper bore (1:10 taper) mates with the taper of the ball screw shaft end and the interference is produced by axial clamping with the lock nut. At installation the lock nut torque was 200Nm (M30×1.5), producing an axial force F=T/(K×d)=200/(0.2×0.03)≈33333N≈33kN. The friction force of the taper fit is F_fric=μ×F_axial×sin(α+ρ)/cosρ=0.15×33000×sin(5.7°+8.5°)/cos8.5°≈0.15×33000×0.247/0.989≈1236N. The coupling transmits a torque T=300Nm, generating a tangential force F_t=T/R=300/0.025=12000N. Since 1236N < 12000N the friction force cannot transmit the torque and the coupling slipped on the shaft. After slipping, the taper surface wore (wear depth about 0.02mm), the taper clearance increased and the coupling loosened axially. After the repair no torque witness mark was made (no line scratched across the coupling and shaft to show their relative position), so loosening could not be judged by visual inspection.
1) Coupling taper bore installation: tighten the lock nut to the manufacturer's torque (200Nm for the M30×1.5 lock nut);
2) Apply a torque witness mark after installation (scratch a line across the coupling end face and the shaft end to make loosening easy to detect);
3) Calibrate the torque wrench (accuracy ±3%);
4) Apply thread-locking compound to the taper fit surface (Loctite 648, medium strength, fills the microscopic clearance);
5) After repair, measure the axial wander of the coupling (dial indicator, axial displacement ≤0.01mm).