E41-515 · Ball Screw Selection · Ball Screw Bearing Outer Ring Spin in Housing · ★★★★
The outer ring of the fixed-end ball screw bearing (angular contact ball bearing 7206C) crept in the housing bore during running. After one year the fit clearance had increased from 0.005mm to 0.03mm and the bearing locating had failed.
The fit between the bearing outer ring and the housing bore was H7/h6 (transition fit, clearance 0~0.012mm). Under the axial force of the ball screw (cutting force F_a=5000N) the outer ring is subjected to alternating radial forces (about 500N) in the bore. After about 10⁶ cycles fretting wear between the outer ring and the bore wall wore about 0.015mm, so the fit clearance increased from 0.005mm to about 0.03mm. The outer ring then moved radially within the clearance (about 0.015mm) and the axial locating accuracy of the ball screw fell (the end-face runout at the locating end increased from 0.002mm to 0.008mm). At the same time the iron powder generated by fretting (about 0.1mg per thousand cycles) entered the bearing interior and accelerated bearing wear.
1) Use an interference fit between the bearing outer ring and the housing bore (J6/js6 instead of H7/h6, interference 0~0.008mm);
2) Apply bearing retaining compound (Loctite 641, fills the microscopic clearance and prevents fretting wear);
3) Housing bore machining accuracy: roundness ≤0.005mm, Ra≤0.8μm;
4) Check the housing bore dimensions regularly (once a year; repair when the wear exceeds 0.01mm);
5) Fit a steel liner in the fixed-end housing bore (the liner is replaced when worn, not the housing).
FT_11_Ball Screw Selection