E41-212 · Guide Rail Selection · Guide Rail Rust Protection in Humid Environments · ★★★
In a workshop during the southern plum-rain season (90% humidity), rust spots appeared on the guide rail surfaces. After one year of operation the rail raceways were severely corroded and slider motion resistance increased.
The guide rail surface was coated with anti-rust oil at the factory (about 0.005mm thick), but in a humid environment the oil was gradually displaced by water (spray/condensation). The rail material, GCr15 bearing steel (1% carbon, 1.5% chromium), has limited corrosion resistance. A chrome-plated rail (coating 0.01~0.02mm) would resist rust effectively, but a plain (uncoated) rail was selected. Corrosion started as pitting on the rail surface (about 0.01mm deep) and progressively spread to the raceway (about 0.03mm deep); raceway roughness worsened from Ra0.4μm to Ra3.2μm and slider motion resistance tripled.
① In humid environments use chrome-plated or stainless-steel guide rails\n② Chrome-plated rails (10μm coating) withstand neutral salt-spray ≥96h\n③ Periodically apply anti-rust oil to the rail surface (weekly)\n④ Install a guide rail protective cover (stainless steel hinged type, condensation-proof)\n⑤ Dehumidify the workshop: keep humidity ≤70% (add dehumidifiers)
FT_10_Linear Guideway Selection