E41-022 · Bearing Selection · Large Fan Main Shaft · ★★★
After about 4000 hours the fan bearing developed abnormal noise and vibration rose from 2.5mm/s to 12mm/s (over limit). Disassembly showed extensive spalling (fatigue pitting) on the inner raceway and rollers, with a deformed cage.
Rated dynamic load Cr=85kN, actual radial load Fr=42kN, equivalent dynamic load P=XFr+YFa≈42kN. Load ratio P/Cr=42/85=0.49 (recommended ≤0.3). Basic rating life L10=(Cr/P)³×10⁶ rev=(85/42)³×10⁶=8.3×10⁶ rev. At rated speed 980rpm, L10h=8.3×10⁶/(60×980)=141h. Even using L10m (median life =5×L10) gives only 705h. The design requirement is 30000h—actual is 1/40, two orders of magnitude short. Additionally, fan blade imbalance causes an extra dynamic load, making the actual equivalent load over 30% higher than calculated.
① Bearing life requirement: L10h≥50000h (continuous-run fans)
② Required rated dynamic load: Cr ≥ P × ∛(L10h×60×n/10⁶)
③ Cr ≥ 42 × ³√(50000×60×980/10⁶)=42׳√2940=42×14.3=600kN
④ Selection: choose double-row spherical roller bearing 22222E (Cr=680kN ✓)
⑤ Confirm installation dimensions: shaft Ø110mm → choose 22222E/W33
⑥ Switch to reinforced (E type) or one size larger bearing
⑦ Additional verification: static load check Co≥P×1.5, limiting speed check
FT_23_Bearing Selection Specification