Grease loss from vertical bearing lacking shield (vertical mixer)

E41-094 · Bearing Selection · Vertical Mixer Bottom Bearing · ★★

Problem Description

The vertical mixer's bottom bearing ran dry and burned after 3 months; disassembly showed no grease inside—all of it had drained from the bottom.

Root Cause

In a vertical mount (shaft vertical), grease slowly flows downward under gravity. The bearing chosen was an open type (no shield), so grease continuously leaked from the bottom opening. Over 3 months about 80% of the grease was lost. Running starved, the rolling elements shifted from elastohydrodynamic lubrication (EHL) to boundary lubrication; the friction coefficient rose from 0.004 to 0.02 and heat generation quintupled, ending in thermal runaway and burnout. Shaft vibration further flung out the grease.

Corrective Solution

① Vertical mounts must use shielded/sealed bearings (2Z/2RS)
② If sealed bearings are unusable, add a grease retainer plate at the bearing bottom (PTFE)
③ Use a high-consistency grease (NLGI#3) to reduce flow
④ Install an automatic timed re-lube system (0.5ml every 8h)
⑤ Provide an oil sump + return port at the housing bottom (recover leaked grease)

Checklist