E41-217 · Bearing Selection · Improper Bearing Mounting · ★★★
Two weeks after installation, the new bearing emitted periodic clicking sounds. Disassembly inspection showed severe cage deformation, some cage pockets enlarged, and rollers skewed.
During installation, a hammering method (copper bar plus hand hammer) was used, and improper operation tilted the bearing as it was pressed onto the journal. During hammering, force was not applied evenly to the inner-ring end face but was deflected onto the cage. The cage, stamped steel (08F), plastically deformed under the impact. After installation, internal clearance was uneven, with rollers skewed in the cage pockets. In operation, the skewed rollers exerted extra thrust on the cage, accelerating cage deformation. Eventually the cage pockets stretched and the rollers fell out.
① Bearing installation must use dedicated pressing tools (press or puller)\n② The force should be applied evenly to the fitted tight ring (press the inner ring when fitting to the shaft; press the outer ring when fitting to the housing bore)\n③ Never transmit installation force through the rolling elements (do not hammer the cage or outer ring to mount the inner ring)\n④ Check the mounting-face perpendicularity before installation (≤0.01 mm)\n⑤ Thermal mounting method: heat the bearing in an oil bath to 80~100℃ then push it onto the journal