E41-221 · Bearing Selection · Newly Installed Motor Bearing Lubrication · ★★
During commissioning of the new motor, the bearing temperature rose rapidly to 95℃. Shutdown inspection found the bearing smoking and grease squeezed out of the seal. Disassembly showed the bearing chamber full of grease.
The standard grease fill for motor bearings is 1/3~1/2 of the bearing internal space, but the operator filled the bearing chamber (including the spaces on both sides of the bearing) to 100%. The excess grease creates huge churning resistance under rolling-element agitation; churning power P_churn=0.5×ρ×ω³×R⁵×C_d. Taking a 6312 bearing as an example (outer diameter 130 mm, speed 1480 rpm), the churning heat from excess grease is about 80 W versus only about 15 W at the correct amount. With five times the heat generation, the bearing temperature quickly rises to 95℃. At high temperature the grease expands in volume and is squeezed out of the seal. Some grease enters the motor interior and contaminates the windings.
① Initial bearing grease fill: 1/3~1/2 of the bearing internal space\n② 1/2~2/3 of the total bearing-chamber capacity (not full)\n③ Metered greasing: use the recommended grams per bearing type from tables (e.g., 6312→12 g)\n④ After greasing, manually rotate the shaft to confirm normal resistance\n⑤ The drain port should be located at the bottom of the bearing chamber (to expel excess grease)
FT_23_Bearing Selection Specification