E41-231 · Bearing Selection · Fan Bearing Condition Monitoring · ★★★★
The induced-draft fan bearing failed suddenly (cage broken, rollers scattered) without any alarm from the vibration-monitoring system. Post-incident analysis of the vibration data found the cage defect frequency already present in the spectrum.
The vibration-monitoring system set its alarm threshold at an overall vibration value of 10 mm/s (ISO 10816-3 standard). The cage defect in its early stage produces a vibration signal at the cage defect frequency FTF=f_r/2×(1-d/D×cosα)=25/2×(1-18/140×cos0)≈11.2 Hz, with an amplitude of only about 1 mm/s—far below the 10 mm/s alarm threshold. The cage-defect signal was buried in the overall vibration and not identified. Only after the cage broke did the overall value exceed 10 mm/s, but by then the bearing was severely damaged. Early fault diagnosis should use spectrum analysis (FFT), not overall-vibration-value monitoring.
① Bearing vibration monitoring should use spectrum analysis (FFT), not overall vibration value\n② Monitor key frequencies: BPFO (outer-race defect), BPFI (inner-race defect), BSF (roller defect), FTF (cage defect)\n③ Cage defect characteristic frequency FTF=f_r/2×(1-d/D×cosα)\n④ Trend analysis is more effective than threshold alarms (warn when FTF amplitude triples)\n⑤ Combined vibration + oil analysis diagnosis (excess Fe in oil + abnormal frequency = confirmed fault)