E41-234 · Bearing Selection · Crusher Bearing-Housing Heat Dissipation · ★★★
Under heavy load the crusher bearing-housing temperature reached 105℃ (normal ≤70℃). Disassembly inspection found the bearing outer-ring/bore contact area was only about 40% (largely point contact).
After finish machining, the bearing housing bore had roundness 0.05 mm (required ≤0.02 mm) and surface roughness Ra6.3 μm (required ≤1.6 μm). The actual contact area between the bearing outer ring and bore was only about 40% (high-point contact), giving a contact thermal resistance R_contact=0.5/K×1/A_actual=0.5/(50×0.4)=0.025 K/W (K is the contact thermal-conductivity coefficient). At a bearing heat generation of 100 W, the contact temperature rise is ΔT=Q×R_contact=100×0.025=2.5℃, a small value. But the actual 40% contact area means higher local heat flux; the microscopic gaps at the fitted surface form an air insulation layer (air thermal conductivity 0.026 W/mK, only 1/8000 of steel), making the equivalent thermal resistance 10× the ideal. The actual temperature rise is ≈25℃; adding the bearing own 30℃ rise gives a total of 55℃, reaching 85℃ at a 30℃ ambient. The measured 105℃ also includes radiation heat and other factors.
① Bearing housing-bore machining requirement: roundness ≤IT6 (0.019 mm @ Φ100), Ra≤1.6 μm\n② Contact ratio ≥75% (check by bluing method; 25×25 mm² area ≥20 contact points)\n③ Scrape the housing bore (raise contact ratio and heat-dissipation capacity)\n④ Apply thermal-conductive silicone grease to the outer ring during installation (fills microscopic gaps, cuts thermal resistance by 80%)\n⑤ Add cooling fins to the housing outer wall (increase heat-dissipation area 30~50%)
FT_23_Bearing Selection Specification