E41-378 · Bearing Selection · Vibration-Motor Bearing Ring Rotation · ★★★★
After 3 months of operation, the vibration-motor (inertia exciter) bearing showed relative rotation between inner ring and shaft (ring rotation), and the journal wore 0.1 mm. The fit was H7/j6 (transition fit), which is unsuitable for vibration service.
The fit selected for the vibration-motor bearing (22316CA, spherical roller bearing) was H7/j6 (transition fit, max clearance 0.005 mm, max interference 0.018 mm). The vibration motor runs at 50 Hz (3000 rpm) and generates a centrifugal force F=50000 N (from the eccentric mass). Under the alternating radial force, fretting occurs at the inner-ring/shaft fitted surface; the transition fit cannot sustain 50000 N of radial force. Fretting wear turned the fit clearance from interference (0.005 mm) to clearance (about 0.1 mm) within 3 months, and the inner ring slid on the shaft (ring rotation). The wear iron powder from ring rotation entered the grease and accelerated bearing raceway wear.
① For vibration service, select an interference fit for the bearing inner ring (k6/m6, interference 0.015~0.035 mm)\n② Journal tolerance: change H7/j6 to k6 (Φ80k6: +0.021/+0.002)\n③ Vibration-motor bearing housing-bore fit: M7 (interference fit, prevents outer-ring rotation)\n④ Apply bearing retaining compound during installation (Loctite 641, compensates small clearance)\n⑤ Regularly check the journal for wear (every 6 months; repair if wear >0.02 mm)
FT_23_Bearing Selection Specification