E41-380 · Bearing Selection · Induced-Draft Fan Bearing-Housing Bolt Fracture · ★★★★★
After 2 years of operation, all the foundation bolts (M30×120) of the induced-draft fan bearing housing fractured; the fan vibrated violently and the housing detached from the foundation, running away.
The induced-draft fan bearing housing is fixed to the concrete foundation by 4 M30 foundation bolts. During operation the fan generates an unbalance force F=0.01×m×r×ω²=0.01×2000×0.1×(157)²≈4930 N (m=2000 kg, r=0.1 mm eccentricity, ω=157 rad/s≈1500 rpm). Each bolt carries alternating tension F_bolt=F/4=1232 N. An M30 bolt (grade 8.8) has a minimum tensile load of about 337 kN, giving a static safety factor of 273. But the bolt carries an alternating load (fan speed 1500 rpm = 25 Hz), about 7.9×10⁸ cycles per year. The stress amplitude σ_a=F_bolt/A_s=1232/561≈2.2 MPa, far below the 50 MPa fatigue limit. However, the bolts were tightened with uneven torque (wrong diagonal sequence), so the most heavily loaded bolt carried about 3000 N, and the thread root had a rolling-process defect (fold crack about 0.2 mm deep), giving an actual peak stress amplitude σ_a_peak=Kt×F_bolt/A_s=3.5×3000/561≈18.7 MPa. After 8×10⁸ cycles the crack propagated to fracture. Once one bolt broke, the remaining 3 overloaded and fractured in a chain.
① Foundation bolt installation: torque wrench, diagonal tightening in 3 steps (M30=800 Nm)\n② Periodically inspect bolts by NDT (annually; magnetic-particle inspection of thread roots)\n③ Upgrade bolt material: grade 8.8 → 10.9 (fatigue strength up 30%)\n④ Add locking nut plus spring washer\n⑤ Periodically balance the fan dynamically (reduce unbalance force, lower bolt load)