E41-384 · Bearing Selection · Excessive Bearing-Housing Oil Level · ★★
The large fan bearing housing (oil lubrication, oil level 2/3) was filled to the full mark after oiling; after 2 h of operation the bearing temperature rose from 45℃ to 80℃. After draining the excess oil, the temperature returned to normal.
For oil lubrication of the bearing housing, the oil level should be at the middle of the sight glass (1/2~2/3 of the sight glass at rest). The operator overfilled past the upper limit (full mark), raising the level about 30 mm above standard. The high level increases the depth of the lower half of the bearing immersed in oil, raising the rolling-element churning resistance. Churning power P_churn=0.5×ρ×ω³×R⁵×C_d×(oil-immersion coefficient)=0.5×900×157³×0.05⁵×1.0×0.8≈2.5 W (about 0.5 W at the normal level). Churning heat increased fivefold, raising the bearing temperature from 45℃ to 80℃. Also, the high level shrinks the oil-air separation space, raising internal housing pressure and venting oil mist from the breather cap. After draining to the standard level, churning heat returned to normal and temperature recovered to 45℃ within 1 h.
① Bearing housing oil-level standard: 1/2~2/3 of sight-glass height (at rest)\n② Add oil while observing the sight glass to avoid overfill\n③ Excessive oil level can raise churning-heat temperature by up to 30℃\n④ When above the upper limit, drain the excess through the drain plug\n⑤ Large bearing housings should use a constant-level oil cup (auto-maintains constant oil level)
FT_23_Bearing Selection Specification