E41-387 · Bearing Selection · High-Temperature Fan Bearing Clearance Loss · ★★★★
The high-temperature fan (inlet temperature 300℃) bearing seized during operation. The inner-ring temperature was 280℃ and the outer-ring temperature 200℃; the 80℃ difference caused the clearance to vanish.
The high-temperature fan bearing sees a high ambient temperature; the inner ring receives heat from the impeller through the shaft (the shaft passes directly through the hot-air zone, about 280℃), while the outer ring dissipates heat through the housing (about 200℃). The inner/outer ring temperature difference is ΔT=80℃. The bearing radial clearance change is ΔCr=α×d×ΔT=12×10⁻⁶×80×80≈0.077 mm. The initial clearance (C4 group, 0.040~0.070 mm) is entirely offset by thermal expansion at an 80℃ difference, turning the clearance negative (interference about 0.007~0.037 mm). The rolling elements are clamped by the inner and outer rings, the friction torque rises sharply, and the bearing temperature spikes → thermal runaway → seizure.
① Bearing clearance selection for high-temperature service: calculate the operating clearance from the inner/outer ring temperature difference\n② Operating clearance = initial clearance − α×d×(ΔT_inner − ΔT_outer)\n③ In this case a C5 clearance group (0.060~0.090 mm) is needed\n④ Or add a thermal-insulation sleeve (reduce shaft heating of the inner ring)\n⑤ Or use a bearing housing with oil cooling (forced cooling of the outer ring, reducing the inner/outer ring temperature difference)
FT_23_Bearing Selection Specification