E41-390 · Bearing Selection · Newly Installed Bearing Excessive Grease · ★★
The newly installed gearbox bearing (6312) temperature rose from 40℃ to 95℃ after 2 h of operation; disassembly found the bearing chamber full of grease and the cage squeezed out of shape by the grease.
When greasing the bearing, the operator filled the bearing chamber (including the spaces on both sides of the bearing) to 100% (standard 1/3~1/2). The excess grease creates huge churning resistance under rolling-element agitation. At 1480 rpm, the 6312 bearing (OD 130 mm, bore 60 mm, width 31 mm) has excess-grease churning power P_churn=0.5×ρ×ω³×R⁵×C_d×f=0.5×900×155³×0.065⁵×1.0×0.8≈80 W (f is the fill factor =1.0). The normal fill (1/3) churns about 15 W. The 80 W churning heat raised the bearing temperature from 40℃ to 95℃ within 2 h. Squeezed by the excess grease (the grease expands another 10% on heating), the cage struts plastically bent (about 0.2 mm deformation).
① Initial bearing grease fill: 1/3~1/2 of the bearing internal space\n② 1/2~2/3 of the total bearing-chamber capacity (not full)\n③ Metered greasing: look up the table by bearing type (6312 → 12 g)\n④ After greasing, rotate the shaft by hand to confirm normal resistance\n⑤ Place the drain port at the bottom of the bearing chamber (to expel excess grease)
FT_23_Bearing Selection Specification