E41-392 · Bearing Selection · Vertical Bearing Low Oil Level · ★★★

Problem Description

The vertically installed bearing (thrust bearing plus cylindrical roller bearing combination) had its oil level about 10 mm below the lower sight-glass limit; after 3 months the roller-end faces were severely worn.

Root Cause

Oil-bath lubrication of a vertical bearing requires the oil level to at least submerge the lowermost rolling element by 1/2. The oil level was at the lower sight-glass limit when filled, but in operation the rolling elements splash the oil, lowering the level slightly (about 2 mm). With the initially low level, it dropped below the rolling elements after running, so the bearing could not get enough oil by splash lubrication. Under oil shortage, boundary lubrication formed between the cylindrical roller end faces and the rib, raising the friction coefficient from 0.005 to 0.03 and accelerating roller-end wear. After 3 months the roller-end wear was about 0.02 mm (standard end-face clearance 0.05 mm); the end-face clearance grew to 0.07 mm, the roller axial location failed, and the cage carried abnormal load.

Corrective Solution

① Vertical bearing oil level: should submerge the lowermost rolling element by 1/2 (upper mark on the sight glass)\n② After filling, run 30 min and check the level (confirm it is at the middle of the sight glass once stable)\n③ Vertical bearings can use oil-mist lubrication (not affected by oil level)\n④ Or use grease lubrication (no need to maintain oil level; consistency ensures lubrication)\n⑤ Check the oil level regularly (monthly; top up immediately if below the lower limit)

Checklist

Reference