Misinterpreted Bearing Vibration Spectrum Causes Unplanned Downtime (Fault Diagnosis)

E41-545 · Bearing Selection · Misdiagnosis of Bearing Vibration Spectrum · ★★★

Problem Symptom

The vibration value of a fan bearing rose from 5mm/s to 8mm/s (alarm at 7mm/s). Spectrum analysis showed a prominent 2× running frequency (50Hz), which was misdiagnosed as a bearing fault. The actual cause was fan impeller unbalance.

Root Cause

The fan ran at 1500r/min (25Hz) and the 2× running frequency (50Hz) dominated the bearing vibration spectrum (6mm/s) while the 1× frequency (25Hz) was 3mm/s. The characteristic bearing fault frequencies are: outer race BPFO=3.05×25=76.3Hz, inner race BPFI=4.95×25=123.8Hz; the 2× frequency of 50Hz is not a bearing fault frequency. However, the maintenance staff wrongly identified 50Hz as a bearing fault (assuming a cage fault frequency FTF≈0.4×25=10Hz or its harmonic at 50Hz). After the bearing was replaced the vibration value was still 8mm/s (no improvement with the new bearing); the actual fault was fan impeller unbalance (dust on the blades, unbalance force about 200N). The signature of impeller unbalance is the 1× frequency (25Hz), but higher harmonics (2× at 50Hz) are also significant. The misinterpretation of the spectrum caused 8h of unplanned downtime plus 5000 yuan for bearing replacement plus the cost of the scrapped new bearing (the old bearing was scrapped but was in fact sound).

Correct Solution

1) Bearing vibration diagnosis should refer to the bearing fault frequency table (calculate BPFO/BPFI/BSF/FTF from the bearing designation);
2) A prominent 2× frequency usually indicates misalignment, looseness or an unbalance harmonic;
3) Bearing fault confirmation: use envelope spectrum analysis (the impact pulse method, which is more sensitive to bearing faults);
4) Perform an impeller balancing test before replacing a bearing;
5) Spectrum analysis should be carried out by experienced personnel or with automatic diagnostic software.

Checklist

References

FT_23_Bearing Selection Standards

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL