E41-584 · Bearing Selection · Vertical Pump Thrust Bearing Installed Reversed · ★★★
The thrust bearing (51120) of a vertical pump (55kW) ran at too high a temperature (85℃) after two months; on disassembly the raceway showed severe wear.
The 51120 single-direction thrust ball bearing was installed in the reverse direction (the shaft washer and housing washer positions were swapped). The bore of the shaft washer (tight ring) of a thrust ball bearing is slightly smaller than that of the housing washer (loose ring); the shaft washer should sit against the shaft shoulder and the housing washer should sit in the housing bore. The housing washer was installed on the shaft and the shaft washer in the housing bore, leaving a 0.08mm gap between the shaft washer and the shaft shoulder, and during running the shaft washer moved slightly on the shaft (fretting wear). At the same time the rolling contact geometry of the bearing changed, the trajectory of the balls in the raceway shifted and the contact stress increased. With correct installation the contact angle is 90°; with incorrect installation it is about 60°, the effective load-carrying area is reduced, the contact stress rises from 600MPa to 900MPa and the life falls by about 70%. In addition the lubricating oil inside the housing cannot reach the ball-raceway contact zone (the oil path is blocked by the housing washer), so poor lubrication accelerates the wear.
1) Before installing a thrust ball bearing, confirm the shaft washer and housing washer (shaft washer on the shaft, housing washer into the housing);
2) The shaft washer must sit tightly against the shaft shoulder (gap ≤0.02mm);
3) The oil path in the housing must deliver lubricant directly to the ball-raceway contact zone;
4) After installation, turn the bearing by hand to check that it rotates smoothly;
5) After a 30min trial run, measure the bearing temperature (≤ambient temperature +40℃).
FT_Bearing Design Handbook