E41-599 · Bearing Selection · Thin-Walled Housing Bearing · ★★★★
A thin-walled aluminium bearing housing (wall thickness 6mm, bore Φ100mm) was used with a 6200 series bearing. After the bearing was fitted the outer ring distorted and the rotation torque increased.
The thin-walled aluminium housing (ZL102 cast aluminium, wall thickness 6mm) was fitted with the bearing outer ring using an H7/p6 interference fit (interference 0.024~0.059mm). The elastic modulus of aluminium E=70GPa (one third of steel) and the wall is only 6mm thick (about D/17), so the stiffness is insufficient. After the outer ring is pressed in the housing deforms elastically (expanding by about 0.02mm); in turn the bearing outer ring is subjected to radial compression and its diameter shrinks by about 0.015mm (as a reaction to the elastic deformation of the aluminium housing). The internal radial clearance of the bearing falls by 0.015mm, so the CN group clearance (0.005~0.015mm) becomes -0.01~0mm (negative clearance). Under negative clearance the contact stress between the balls and the raceway rises and the friction torque increases, raising the temperature. In addition the thermal expansion coefficient of aluminium (23×10⁻⁶/℃) is twice that of the bearing steel (12×10⁻⁶/℃), so at a working temperature rise of 30℃ the housing expands 0.033mm more than the bearing outer ring, further increasing the interference or changing the clearance.
1) A thin-walled housing should use a transition fit (H7/js6 or H7/k6) and avoid an interference fit;
2) Locate the bearing outer ring axially (retaining ring or end cap) rather than by radial interference;
3) Where the wall is too thin, thicken the housing or insert a steel sleeve (wall thickness ≥D/10);
4) The effect of the thermal expansion difference of the aluminium housing on the clearance must be checked;
5) Change to housed bearings (the UCP series, designed for aluminium and thin-walled housings).
FT_Bearing Design Handbook