E41-032 · Reducer/Coupling Selection · Continuous Conveyor Line · ★★
After 8 h of continuous operation, the reducer housing temperature reached 95 ℃; oil began seeping from the oil seal and the oil temperature reached 85 ℃ (recommended maximum 80 ℃). It recovered after shutdown and cooling, but recurred daily.
The reducer thermal power P_th=3.5 kW (without cooling fan) and the actual input power P_in=5.5 kW. Reducer efficiency η=0.94, power loss P_loss=P_in×(1-η)=5.5×0.06=0.33 kW, seemingly far below the thermal power. But besides transmission loss, actual heat generation also includes oil-churning loss, bearing-friction loss, and seal-friction loss; under continuous high-speed operation the oil-churning loss alone can reach 2~3% of input power. Total heat generation Q_total≈P_in×f_loss≈5.5×0.04=0.22 kW. Although not large, the reducer housing has limited heat-dissipation area (about 0.8 m²), and at 85 ℃ the oil temperature had brought natural-convection surface cooling to equilibrium, so no further heat could be dissipated. Thermal-balance temperature = T_ambient+Q/(h×A)=20+220/(12×0.8)=43 ℃? That is wrong; the actual 95 ℃ indicates that the cooling condition is worse than theory (confined space, heat-dissipation surfaces covered by material, poor ventilation).
① Thermal-power verification formula: P_th ≥ P_in × (1-η) × f_ambient
② f_ambient is the ambient-temperature factor: 1.0 at 40 ℃, 0.9 at 35 ℃, 0.8 at 30 ℃... In this example the environment is 40 ℃ so take 1.0
③ Required P_th=5.5×(1-0.94)×1.0=0.33 kW, but actual heat is larger (oil-churning loss, etc.)
④ Correct method: select per the reducer manufacturer's thermal-power table; at a 20 ℃ temperature differential P_th=3.5 kW corresponds to P_in≤3.5 kW
⑤ Option A: add a cooling fan (P_th raised to 6 kW ✓)
⑥ Option B: add a water-cooling coil (external oil-circulation cooling)
⑦ Oil upgrade: switch to synthetic oil (allowable oil temperature 120 ℃, 40 ℃ higher than mineral oil)
FT_13_Reducer-Motor Matching Selection