E41-034 · Reducer/Coupling Selection · High-Speed Engraving-Machine Spindle Feed · ★★★
At a feed rate of 12 m/min the whole machine resonated strongly and the machined surface showed fish-scale markings. The resonance disappeared when speed was lowered or raised, but persisted in the 11~13 m/min range. Frequency analysis showed a vibration frequency of about 85 Hz.
The flexible coupling torsional stiffness K_c=0.5 Nm/arcmin (jaw-type polyurethane elastomer). Together with the ballscrew system torsional stiffness, motor-rotor inertia, and load inertia, it forms a multi-degree-of-freedom torsional vibration system. The system first-order torsional natural frequency ω_n=√(K_eq/J_eq), where K_eq is the equivalent stiffness (including coupling stiffness + ballscrew torsional stiffness + bearing/nut stiffness) and J_eq is the equivalent inertia referred to the motor shaft. The calculated first-order torsional natural frequency is about 85 Hz, corresponding to ballscrew speed n=85×60/lead (p=10 mm)=510 rpm, corresponding to feed rate v=510×10=5100 mm/min=5.1 m/min. But the actual resonance occurs at 12 m/min (about 1200 rpm), indicating a higher-order mode (possibly the ballscrew axial-vibration mode or the coupled coupling+ballscrew mode). The low stiffness of the coupling is the weak link of the whole transmission chain, accounting for over 60% of the total system stiffness.
① The transmission-system torsional natural frequency should avoid the operating frequency by ±20%
② Coupling selection: torsional stiffness K_c should dominate the system total stiffness (≥5 times the system stiffness)
③ Recommended: metallic diaphragm coupling (K_c≥10 Nm/arcmin, 20 times higher than flexible coupling)
④ Verification: with diaphragm coupling K_c=15 Nm/arcmin, the system natural frequency shifts to ≥500 Hz, far above the operating frequency
⑤ Increase transmission-system stiffness: enlarge the ballscrew diameter (d=25→32 mm), increase bearing preload
⑥ Servo filter: use a notch filter to suppress the 85 Hz resonance
FT_13_Reducer-Motor Matching Selection