E41-247 · Reducer Coupling Selection · Belt-Conveyor Coupling · ★★★
The belt-conveyor elastic pin coupling (nylon pin) frequently shears in service — averaging 2 breaks/month, each requiring a 2 h shutdown to replace.
The elastic pin coupling (type HL5, pin Φ18 mm, 8 pins, nylon 66) has motor power 75 kW; rated torque T_nom = 9550×P/n = 9550×75/1480 ≈ 484 Nm. Start-up impact torque T_peak = 2.5×T_nom = 1210 Nm (no-load start); single-pin shear force F = T_peak/(R×n) = 1210/(0.18×4) = 1680 N (only 4 pins carry load due to uneven loading from misalignment). Nylon pin shear strength ~50 MPa; single-pin area A = π×9² = 254 mm²; allowable shear F_allowed = 50×254 = 12700 N, far above 1680 N. Actual shearing cause: coupling misalignment 0.3 mm means only 2 of 4 pins bear most load, unevenly. Meanwhile the pin hole wears elliptical (long axis Φ18.5 mm); the pin rattles in the hole and breaks under alternating bending stress.
① Coupling alignment requirement: radial ≤0.05 mm, angular ≤0.05°\n② After pin-hole wear, ream and fit oversized pins (Φ18 → Φ20 mm)\n③ Upgrade pin material: nylon 66 → MC nylon (strength +30%)\n④ Install cushion washers (rubber washers absorb impact)\n⑤ Switch to a jaw-type coupling (whole-elastomer replacement, better fault tolerance)
FT_13_Reducer-Motor Matching Selection