E41-401 · Reducer Coupling Selection · Robot Cycloidal Reducer Pin-Gear-Pin Fracture · ★★★★
A robot-joint cycloidal reducer at high speed (2000 rpm input) suddenly seizes; disassembly finds a pin-gear pin fractured at the root, with fragments wedged between the cycloidal disc and pins.
The cycloidal reducer's pin-gear pins (diameter 6 mm, length 30 mm, material GCr15, HRC60) are fixed in the pin housing; the cycloidal disc orbits around them. In operation the pins see alternating contact stress from the disc flank. Contact stress σ_H = 0.388×√(2000×206000²/3²) ≈ 3200 MPa (disc flank squeeze on pin ~2000 N). The pin bending-fatigue limit is ~800 MPa (GCr15), far below 3200. But in normal operation the pins mainly see compressive (not bending) stress; actual cyclic stress amplitude ~100 MPa, so they should not break. However, the robot joint's impact load (at start/stop) puts bending impact stress on the pins σ_bend = M/W = 5/0.0212 ≈ 236 MPa (impact bending moment ~5 Nm); the larger stress amplitude causes fatigue cracks at the root (stress concentration) after ~10⁶ cycles, then fracture.
① Upgrade cycloidal pin material: GCr15 → carburized bearing steel (surface HRC62, tough core)\n② Pin root fillet R ≥ 0.5 mm (reduce stress concentration)\n③ Add a torque limiter to the robot-joint reducer (prevent impact overload)\n④ Regularly inspect pins (annually, magnetic-particle inspection for cracks)\n⑤ Choose branded cycloidal reducers (pin machining precision and heat treatment assured)
FT_13_Reducer-Motor Matching Selection