E41-405 · Reducer Coupling Selection · Flange-Mounted Reducer Register Loosening · ★★★
A flange-mounted reducer (B5 flange) in operation shows its motor-to-reducer flange register loosening; the concentricity between motor shaft and reducer input shaft drifts 0.15 mm.
The reducer flange register (Φ250H7/h6, clearance 0~0.052 mm) mates with the motor flange. No anti-loosening adhesive was applied at installation; only 4 M16 bolts held it. In operation, motor start/stop impact torque (T_peak = 2×T_nom = 200 Nm) produces radial force F = T/R = 200/0.125 = 1600 N. The register-fit friction F_fric = μ×F_pre×n = 0.15×72.5×4 = 43.5 kN (M16 bolt preload F_pre = 72.5 kN, μ = 0.15), far above 1600 N, so it should not move in theory. But under long-term vibration the register fit fretted (fretting wear); clearance grew from 0.02 mm to 0.08 mm, and the register lost its locating function. With 0.08 mm clearance the motor and reducer shafts shift relative to each other; the coupling sees extra radial force, accelerating elastomer wear.
① Flange register fit precision: H7/h6 (clearance ≤0.05 mm)\n② Apply anti-loosening adhesive on the register face (Loctite 641, fills clearance to prevent fretting)\n③ Add locating pins at installation (Φ10h6, 2 pcs, diagonal)\n④ Tighten flange bolts with a torque wrench in diagonal sequence\n⑤ Re-check flange bolt torque after 24 h running
FT_13_Reducer-Motor Matching Selection