E41-413 · Reducer Coupling Selection · Reducer Gear Tooth-Tip Wear · ★★★
The high-speed shaft pinion (z=19) shows clear abrasive-wear tracks at the tooth tips; the tips become pointed and the tooth thickness is reduced from 45 mm to 43 mm (a 4.4% reduction).
Contaminants in the reducer oil (particle size 10~50 μm) mainly come from running-in gear wear debris and external dust. The oil filter (rating 100 μm) cannot capture debris below 50 μm, so it circulates in the oil. The tooth-tip region (where the relative sliding velocity is highest) has the thinnest oil film (~0.5 μm), allowing abrasive particles to penetrate to the metal contact surface. Particles (hardness ~HV700, close to the tooth-surface hardness of HV700) cause abrasive wear at the tips, at a rate of about 0.005 mm/1000 h. After 4 years the tip wear is about 0.2 mm (tooth thickness reduced 0.4 mm). As the tips sharpen, the contact ratio drops (ε=1.4 to ε=1.2), the meshing impact grows, and noise rises from 75 dB to 85 dB.
① Reducer oil filtration rating should be ≤25 μm (β₂₅ ≥ 100)\n② Change oil and clean the filter periodically (every 6 months or per oil-analysis results)\n③ Inspect tooth-tip wear (measure with a tooth-thickness caliper every 2 years)\n④ Replace the gear when wear exceeds 10% of tooth thickness\n⑤ For severe abrasive wear, add a magnetic separator (to capture ferromagnetic debris)
FT_13_Reducer-Motor Matching Selection