E41-575 · Gearbox & Coupling Selection · Gearbox Insufficient Selection Safety Factor · ★★★★
A gearbox (model SA67, rated torque 1200Nm) driving a conveyor ran at an actual load torque of 1100Nm (a load ratio of 91.7%); after three years the gear tooth flanks were severely worn and the gearbox needed replacement.
The rated torque of the gearbox is 1200Nm and the actual load torque is 1100Nm, a load ratio of 91.7% (recommended ≤80%). The gear contact fatigue life works out as L10=(T_rated/T_actual)^3×L10_rated=(1200/1100)^3×20000=1.09³×20000≈25900h, longer than the rated life (20000h). However, the actual service conditions include impact loads (T_peak=2×T_nom=2400Nm when the conveyor starts). Under impact loading the equivalent torque is T_eq=(ΣT_i³×t_i/T)^(1/3)=[(1100³×0.95+2400³×0.05)/1]^(1/3)≈(1.27×10⁹+6.91×10⁹)^(1/3)=(8.18×10⁹)^(1/3)≈2015Nm. The equivalent torque of 2015Nm exceeds the rated torque of 1200Nm by 68%, and the actual life is L10=(1200/2015)^3×20000=0.595³×20000≈4200h. Three years (about 17500h) far exceeds 4200h, so the tooth flanks wore severely (about 0.5mm of tooth thickness lost). The selection safety factor of the gearbox was insufficient (SF=T_rated/T_actual=1200/1100=1.09, recommended ≥1.5), so the life was far below expectations.
1) Use a selection safety factor ≥1.5 for the gearbox (allowing for impact loads and the actual duty);
2) Calculate the equivalent torque with impact loads: T_eq=(ΣT_i³×t_i/T)^(1/3);
3) In this case select an SA77 (rated torque 1600Nm, SF=1600/1100=1.45);
4) Use a soft start on the motor (reducing the starting shock and extending the gearbox life);
5) Select one size larger gearbox (a 20% increase in initial investment doubles the life).
FT_13_Gearbox and Motor Matching Selection