E41-141 · Cylinder and Hydraulic Selection · Electro-Hydraulic Servo Control System · ★★★★★
The electro-hydraulic servo system is normal during commissioning, but after 2 weeks of operation the servo valve sticks frequently, system response slows, and positioning accuracy degrades from ±0.01 mm to ±0.1 mm.
The servo valve's nozzle-flapper gap is only 0.02~0.04 mm and demands oil cleanliness NAS 1638 grade 6 (≥6 μm particles ≤32000/100 ml). The system used new hydraulic oil at cleanliness NAS grade 8 and had no high-pressure or return filter. After 2 weeks the wear particles in the oil (pump wear + line weld slag) degraded cleanliness to NAS grade 10 (≥6 μm particles ~128000/100 ml). Particles jam the servo valve's throttling edge, increasing spool motion resistance; response time stretches from 5 ms to 30 ms and hysteresis grows from 0.5% to 3%. Moreover, particles wear the spool's sharp edges, increasing internal leakage and dropping system pressure from 21 MPa to 18 MPa.
① Servo-system oil cleanliness must be ≥ NAS grade 6
② Add in-line filtration: high-pressure filter (β₃ ≥ 1000) + return filter (β₁₀ ≥ 100)
③ New oil must be filtered before filling (3 μm rating, recirculating filtration for 24 h)
④ Add a magnetic separator to the tank (to capture ferromagnetic particles)
⑤ Take periodic samples for testing (monthly, particle counter to check NAS grade)
FT_32_Hydraulic System Design